Motion Control
Control loop time |
1 or 2 ms depending on module configuration |
Maximum speed |
65,535 user-defined position units per second |
RS232 Port
Interface with Delta’s RMCWin software and the RMCLink ActiveX Control and .NET Assembly Component |
Requires a PC running Windows 98/NT/2000/Me/XP/Vista/7. |
Connector |
DB9 Male DTE |
Cable |
Null modem to a PC |
RJ-11 LCD Terminal Jack
Interface with Delta’s optional four-line, 20-character LCD display with keypad |
Allows viewing status information, changing parameters, and issuing commands. |
Power
Voltage |
+24 VDC ±20% |
Current - 2 axes (3 slots) |
Typical 290 mA @ 24 VDC, max 375 mA |
4 axes (4 slots) |
Typical 385 mA @ 24 VDC, max 500 mA |
6 axes (5 slots) |
Typical 485 mA @ 24 VDC, max 625 mA |
8 axes (6 slots) |
Typical 585 mA @ 24 VDC, max 750 mA |
DC-DC converter isolation |
500 VAC, 700 VDC, input to controller |
Mechanical
Dimensions - 2 axes (3 slots) |
4.12 x 5.95 x 4.75 in (10.5 x 15.0 x 12.1 cm) (WxHxD) |
8 axes (6 slots) |
7.12 x 5.95 x 4.75 in (18.1 x 15.0 x 12.1 cm) (WxHxD) |
Weight - 2 axes (3 slots) |
2.0 lb (0.9 kg) max |
8 axes (6 slots) |
3.0 lb (1.4 kg) max |
Mounting
Options |
Symmetrical DIN 3 or panel-mount |
Orientation |
The RMC should be mounted upright on a vertical surface, such that the air holes are on top and bottom. |
Clearance, above and below |
The amount of clearance required depends on the maximum ambient temperature: Above 122°F (50°C) 3 in (7.6 cm) 86 to 122°F (30 to 50°C) 2 in (5.1 cm) Less than 86°F (30°C) 1 in (2.5 cm) |
Environment
Operating temperature |
+32 to +140°F (0 to +60°C) |
Storage temperature |
-40 to +185°F (-40 to +85°C) |
Humidity |
93%, non-condensing |
Compliance |
CE, UL, Canadian UL (see details below) |
Agency Compliance
CE Tests Performed |
See also General Wiring Information. |
Radiated Emissions |
EN55022 Class A |
Conducted Emissions |
EN55022 Class A |
Electrostatic Discharge |
EN61000-4-2 ±4 kV contact |
Radiated Immunity |
EN61000-4-3 3 V/m |
Electrical Fast Transient Burst |
EN61000-4-4 1 kV (A/C) |
Conducted Immunity |
EN61000-4-6 3 V rms |
UL, C-UL Specifics |
See also General Wiring Information. |
File Number |
E141684 |
Failsafe Timers
No internal bus activity |
After 15µs, the drive outputs are disabled. |
Software watchdog |
After 26ms, the module resets and drive outputs are disabled if the microprocessor does not retrigger the onboard watchdog timer. |
Flash Memory Storage
Retention Time |
10 years at 150°C, 20 years at 125°C |
Write/erase Cycles |
100,000 minimum |
Transducer Inputs and Drive Outputs
See the appropriate section(s):
Digital I/O
See Digital I/O Specifications
Communication Modules
See the appropriate section(s):