For general specifications on the RMC, see RMC100 Specifications.
Transducer Inputs
Axes |
Two per module |
Inputs |
Two RS422 differential |
Clock outputs |
Two RS422 differential |
Clock frequency |
220 kHz |
Cable type |
Twisted pair, shielded |
Cable length maximum |
Transducer dependent (approx. 300-600 ft) |
ESD protection |
15 kV |
Resolution |
Transducer dependent (up to 2 mm or approximately 0.00008" for MDTs) |
Count encoding |
Binary or Gray Code |
Count data length |
4 to 32 bits |
Drive Outputs
Range |
±10 V @ 5 mA (2 kW or greater load) (For current drive, use the VC2100 accessory: |
Tolerance |
At 10 V: +200 mV, -100 mV |
Resolution |
12 bits |
Output isolation |
750 VDC, optically isolated |
Overload protection |
One-second short-circuit duration |
Overvoltage protection |
Outputs are protected by clamp diodes |
See also: