For general specifications on the RMC, see RMC100 Specifications. See SSI Overview for details on using MDTs with SSI output.
MDT Interface
Axes |
Two per module |
Inputs |
Two RS422 differential (can also be used single-ended) |
Outputs |
Two RS422 differential (can also be used single-ended) |
ESD protection |
15kV |
Resolution |
0.001" Start/Stop; 0.0001" PWM |
Circulations |
1 Start/Stop; up to 16 PWM |
Count rate |
120MHz |
Drive Outputs
Range |
±10 V @ 5 mA (2 kW or greater load) (For current drive, use the VC2100 accessory: |
Tolerance |
At 10 V: +200 mV, -100 mV |
Resolution |
12 bits |
Output isolation |
750 VDC, optically isolated |
Overload protection |
One-second short-circuit duration |
Overvoltage protection |
Outputs are protected by clamp diodes |