MDT Specifications

For general specifications on the RMC, see RMC100 Specifications. See SSI Overview for details on using MDTs with SSI output.

 

MDT Interface

Axes

Two per module

Inputs

Two RS422 differential (can also be used single-ended)

Outputs

Two RS422 differential (can also be used single-ended)

ESD protection

15kV

Resolution

0.001" Start/Stop; 0.0001" PWM

Circulations

1 Start/Stop; up to 16 PWM

Count rate

120MHz

 

Drive Outputs

Range

±10 V @ 5 mA (2 kW or greater load)

(For current drive, use the VC2100 accessory:
±10 mA to ±200 mA in 10 mA steps)

Tolerance

At 10 V: +200 mV, -100 mV
At 0 V: ±50 mV
At -10 V: +100 mV, -200 mV

Resolution

12 bits

Output isolation

750 VDC, optically isolated

Overload protection

One-second short-circuit duration

Overvoltage protection

Outputs are protected by clamp diodes

 

See also:

MDT Overview

MDT Wiring

MDT Configuration

MDT LED Indicators

 


Copyright (c) 1997-2015 by Delta Computer Systems, Inc.