RMC150 Registers, File 45: Communication Configuration

AB

DF1,CSP
Address

Modbus
TCP
,RTU
Address

FINS

Address

External

Data Type

Internal

IEC
Address

Internal
Data Type

Access

Register Name

F45:0-3

23041-

23047

D23040-D23046

-

%MD45.0-3

-

-

Reserved

F45:4

23049

D23048

REAL

%MD45.4

DINT

Read/Write

ClosedPROFIBUS: Station Address

Indicates the current PROFIBUS station address for this controller. Valid values are 1 to 126. The default is 126, which is reserved for unaddressed PROFIBUS devices.

 

NOTE: Only RMC150E controllers with the PROFIBUS communication module installed have this register.

F45:5

23051

D23050

REAL

%MD45.5

DINT

Read/Write

ClosedPROFIBUS: Lock Address

0=unlocked, 1=locked

 

This register controls whether the PROFIBUS Station Address can be changed over PROFIBUS by a Class 2 master. Notice that RMCTools can always change the station address, regardless of the value of this register. Also, setting the station address over RMCTools will set this register to zero (0).

 

NOTE: Only RMC150E controllers with the PROFIBUS communication module installed have this register.

F45:6

23053

D23052

DWORD

%MD45.6

DWORD

Read Only

PROFIBUS Connection Status

F45:7

23055

D23054

DINT

%MD45.7

-

-

Reserved

F45:8

23057

D23056

DWORD

%MD45.8

DWORD

Read Only

ClosedMAC Address (bytes 0-3)

big Endian, (for 00-50-A0-B1-23-45, this would be 0x0050A0B1)

F45:9

23059

D23058

DWORD

%MD45.9

DWORD

Read Only

ClosedMAC Address (bytes 4-5)

big Endian, in upper 16 bits (for 00-50-A0-B1-23-45, this would be 0x23450000)

F45:10

23061

D23060

DWORD

%MD45.10

DWORD

Read Only

Ethernet Status Bits

F45:11

23063

D23062

DWORD

%MD45.11

DWORD

Read/Write

Ethernet Configuration Bits

F45:12

23065

D23064

DWORD

%MD45.12

DWORD

Read/Write

IP Address

F45:13

23067

D23066

DWORD

%MD45.13

DWORD

Read/Write

Subnet Mask (0=use standard network masks)

F45:14

23069

D23068

DWORD

%MD45.14

DWORD

Read/Write

Default Gateway (0=none)

F45:15

23071

D23070

DWORD

%MD45.15

DWORD

Read Only

DHCP (or BOOTP) server IP Address

F45:16

23073

D23072

DINT

%MD45.16

DINT

Read Only

DHCP Lease Start (seconds since powerup)

F45:17

23075

D23074

DINT

%MD45.17

DINT

Read Only

DHCP Lease End (seconds since powerup)

F45:18

23077

D23076

DINT

%MD21.18

DINT

Read/Write

EtherNet/IP Class 1 TTL (time-to-live)

F45:19

23079

D23078

DINT

%MD245.19

DINT

Read/Write

EtherNet/IP Class 1 Start of Multicast Address Block

F45:20

23081

D23080

DINT

%MD45.20

DINT

Read/Write

EtherNet/IP Class 1 Size of Multicast Address Block

F45:21

23083

D23082

DWORD

%MD45.21

DWORD

Read/Write

Ethernet Outgoing Cyclic I/O Data Source

F45:22

23085

D23084

DWORD

%MD45.22

DWORD

Read/Write

Ethernet Incoming Cyclic I/O Data Destination

F45:23

23087

D23086

DWORD

%MD45.23

DWORD

Read Only

I/O Connection Status

F45:24

23089

D23088

DINT

%MD45.24

DINT

Read Only

I/O Connection PLC State

F45:25

23091

D23090

DINT

%MD45.25

DINT

Read/Write

ClosedEthernet App Flags

Bits 0-3 - I/O Data Mode

0=Use a Sync Register

1=Do not use a Sync Register

Applies to both EtherNet/IP and PROFINET.

 

Bits 4 - 5 - PROFINET Byte Order

0=MSB first

1=LSB first

Applies to PROFINET.

 

F45:26-55

23093-

23151

D23092-

D23150

-

%MD45.26-55

-

-

Reserved

F45:56-115

23153-

23271

D23152-

D23270

DWORD

%MD45.56-115

DWORD

Read/Write

PROFINET Device Name

Each register in this range holds four characters of the PROFINET device name.

F45:116

23273

D23272

DWORD

%MD45.116

DWORD

Read/Write

PROFINET Custom Data Record 1000 Address

F45:117

23275

D23274

DWORD

%MD45.117

DWORD

Read/Write

PROFINET Custom Data Record 1001 Address

F45:118

23277

D23276

DWORD

%MD45.118

DWORD

Read/Write

PROFINET Custom Data Record 1002 Address

F45:119

23279

D23278

DWORD

%MD45.119

DWORD

Read/Write

PROFINET Custom Data Record 1003 Address

 