RMC75 Registers, File 21: Communication Configuration

AB

DF1,CSP
Address

Modbus
TCP
,RTU
Address

FINS

Address

External

Data Type

Internal

IEC
Address

Internal
Data Type

Access

Register Name

RMC75E

F21:0-7

10753-10767

D10752-

D10766

-

%MD21.0-7

-

Read Only

Reserved

F21:8

10769

D10768

DWORD

%MD21.8

DWORD

Read Only

ClosedMAC Address (bytes 0-3)

big Endian, (for 00-50-A0-A1-23-45, this would be 0x0050A0A1)

F21:9

10771

D10770

DWORD

%MD21.9

DWORD

Read Only

ClosedMAC Address (bytes 4-5)

big Endian, in upper 16 bits (for 00-50-A0-A1-23-45, this would be 0x23450000)

F21:10

10773

D10772

DWORD

%MD21.10

DWORD

Read Only

Ethernet Status Bits

F21:11

10775

D10774

DWORD

%MD21.11

DWORD

Read/Write

Ethernet Configuration Bits

F21:12

10777

D10776

DWORD

%MD21.12

DWORD

Read/Write

IP Address

F21:13

10779

D10778

DWORD

%MD21.13

DWORD

Read/Write

Subnet Mask (0=use standard network masks)

F21:14

10781

D10780

DWORD

%MD21.14

DWORD

Read/Write

Default Gateway (0=none)

F21:15

10783

D10782

DWORD

%MD21.15

DWORD

Read Only

DHCP (or BOOTP) server IP Address

F21:16

10785

D10784

DINT

%MD21.16

DINT

Read Only

DHCP Lease Start (seconds since powerup)

F21:17

10787

D10786

DINT

%MD21.17

DINT

Read Only

DHCP Lease End (seconds since powerup)

F21:18

10789

D10788

DINT

%MD21.18

DINT

Read/Write

EtherNet/IP Class 1 TTL (time-to-live)

F21:19

10791

D10790

DINT

%MD21.19

DINT

Read/Write

EtherNet/IP Class 1 Start of Multicast Address Block

F21:20

10793

D10792

DINT

%MD21.20

DINT

Read/Write

EtherNet/IP Class 1 Size of Multicast Address Block

F21:21

10795

D10794

DWORD

%MD21.21

DWORD

Read/Write

Ethernet Outgoing Cyclic I/O Data Source

F21:22

10797

D10796

DWORD

%MD21.22

DWORD

Read/Write

Ethernet Incoming Cyclic I/O Data Destination

F21:23

10799

D10798

DWORD

%MD21.23

DWORD

Read Only

I/O Connection Status

F21:24

10801

D10800

DINT

%MD21.24

DINT

Read Only

I/O Connection PLC State

F21:25

10803

D10802

DINT

%MD21.25

DINT

Read/Write

ClosedEthernet App Flags

Bits 0-3 - I/O Data Mode

0=Use a Sync Register

1=Do not use a Sync Register

Applies to both EtherNet/IP and PROFINET.

 

Bits 4 - 5 - PROFINET Byte Order

0=MSB first

1=LSB first

Applies to PROFINET.

 

F21:26-55

10805-

10863

D10804-

D10862

-

%MD21.26-55

-

-

Reserved

F21:56-115

10865-

10983

D10864-

D10982

DWORD

%MD21.56-115

DWORD

Read/Write

PROFINET Device Name

Each register in this range holds four characters of the PROFINET device name.

F21:116

10985

D10984

DWORD

%MD21.116

DWORD

Read/Write

PROFINET Custom Data Record 1000 Address

F21:117

10987

D10986

DWORD

%MD21.117

DWORD

Read/Write

PROFINET Custom Data Record 1001 Address

F21:118

10989

D10988

DWORD

%MD21.118

DWORD

Read/Write

PROFINET Custom Data Record 1002 Address

F21:119

10991

D10990

DWORD

%MD21.119

DWORD

Read/Write

PROFINET Custom Data Record 1003 Address

RMC75S

F21:0

10753

D10752

REAL

%MD21.0

DINT

Read Only

RS-232 Monitor Baud Rate

F21:1

10755

D10754

REAL

%MD21.1

DWORD

Read Only

RS-232 Monitor Configuration Bits

F21:2

10757

D10756

REAL

%MD21.2

DINT

Read Only

RS-232 Monitor Protocol

F21:3

10759

D10758

REAL

%MD21.3

DINT

Read Only

RS-232 Monitor Address

F21:4

10761

D10760

REAL

%MD21.4

DINT

Read/Write

Comm. Serial Baud Rate

F21:5

10763

D10762

REAL

%MD21.5

DWORD

Read/Write

ClosedComm. Serial Bits

0-1

Comm. Serial Data Bits

2

Comm. Serial Stop Bits

3-4

Comm. Serial Parity

5-6

Comm. Serial Line Driver

7

Comm. Serial Checksum Type

8-9

Comm. Serial Data Type

10

FlowControl

11

DF1: Allow Duplicate Packet Detection

F21:6

10765

D10764

REAL

%MD21.6

DINT

Read/Write

Comm. Serial Protocol

F21:7

10767

D10766

REAL

%MD21.7

DINT

Read/Write

Comm. Serial Address

RMC75P

F21:0

10753

D10752

REAL

%MD21.0

DINT

Read Only

RS-232 Monitor Baud Rate

F21:1

10755

D10754

REAL

%MD21.1

DWORD

Read Only

RS-232 Monitor Configuration Bits

F21:2

10757

D10756

REAL

%MD21.2

DINT

Read Only

RS-232 Monitor Protocol

F21:3

10759

D10758

REAL

%MD21.3

DINT

Read Only

RS-232 Monitor Address

F21:4

10761

D10760

REAL

%MD21.4

DINT

Read Only

ClosedPROFIBUS: Station Address

Indicates the current PROFIBUS station address, as selected by the rotary switches on the front of the RMC75P. Possible values are from 0-99, although zero (0) is not a valid station address.

F21:5

10763

D10762

-

%MD21.5

-

-

Reserved

F21:6

10765

D10764

DWORD

%MD21.6

DWORD

Read Only

PROFIBUS Connection Status

 

 

See Also

RMC75 Register Map Overview


Send comments on this topic.