RMC75 Registers, File 21: Communication Configuration
AB |
Address |
External |
Internal IEC |
Internal |
Access |
Register Name |
|
RMC75E |
|||||||
F21:0-7 |
10753-10767 |
D10752- D10766 |
- |
%MD21.0-7 |
- |
Read Only |
Reserved |
F21:8 |
10769 |
D10768 |
DWORD |
%MD21.8 |
DWORD |
Read Only |
|
F21:9 |
10771 |
D10770 |
DWORD |
%MD21.9 |
DWORD |
Read Only |
|
F21:10 |
10773 |
D10772 |
DWORD |
%MD21.10 |
DWORD |
Read Only |
|
F21:11 |
10775 |
D10774 |
DWORD |
%MD21.11 |
DWORD |
Read/Write |
|
F21:12 |
10777 |
D10776 |
DWORD |
%MD21.12 |
DWORD |
Read/Write |
IP Address |
F21:13 |
10779 |
D10778 |
DWORD |
%MD21.13 |
DWORD |
Read/Write |
Subnet Mask (0=use standard network masks) |
F21:14 |
10781 |
D10780 |
DWORD |
%MD21.14 |
DWORD |
Read/Write |
Default Gateway (0=none) |
F21:15 |
10783 |
D10782 |
DWORD |
%MD21.15 |
DWORD |
Read Only |
DHCP (or BOOTP) server IP Address |
F21:16 |
10785 |
D10784 |
DINT |
%MD21.16 |
DINT |
Read Only |
DHCP Lease Start (seconds since powerup) |
F21:17 |
10787 |
D10786 |
DINT |
%MD21.17 |
DINT |
Read Only |
DHCP Lease End (seconds since powerup) |
F21:18 |
10789 |
D10788 |
DINT |
%MD21.18 |
DINT |
Read/Write |
EtherNet/IP Class 1 TTL (time-to-live) |
F21:19 |
10791 |
D10790 |
DINT |
%MD21.19 |
DINT |
Read/Write |
EtherNet/IP Class 1 Start of Multicast Address Block |
F21:20 |
10793 |
D10792 |
DINT |
%MD21.20 |
DINT |
Read/Write |
EtherNet/IP Class 1 Size of Multicast Address Block |
F21:21 |
10795 |
D10794 |
DWORD |
%MD21.21 |
DWORD |
Read/Write |
Ethernet Outgoing Cyclic I/O Data Source |
F21:22 |
10797 |
D10796 |
DWORD |
%MD21.22 |
DWORD |
Read/Write |
Ethernet Incoming Cyclic I/O Data Destination |
F21:23 |
10799 |
D10798 |
DWORD |
%MD21.23 |
DWORD |
Read Only |
|
F21:24 |
10801 |
D10800 |
DINT |
%MD21.24 |
DINT |
Read Only |
|
F21:25 |
10803 |
D10802 |
DINT |
%MD21.25 |
DINT |
Read/Write |
|
F21:26-55 |
10805- 10863 |
D10804- D10862 |
- |
%MD21.26-55 |
- |
- |
Reserved |
F21:56-115 |
10865- 10983 |
D10864- D10982 |
DWORD |
%MD21.56-115 |
DWORD |
Read/Write |
PROFINET Device Name Each register in this range holds four characters of the PROFINET device name. |
F21:116 |
10985 |
D10984 |
DWORD |
%MD21.116 |
DWORD |
Read/Write |
PROFINET Custom Data Record 1000 Address |
F21:117 |
10987 |
D10986 |
DWORD |
%MD21.117 |
DWORD |
Read/Write |
PROFINET Custom Data Record 1001 Address |
F21:118 |
10989 |
D10988 |
DWORD |
%MD21.118 |
DWORD |
Read/Write |
PROFINET Custom Data Record 1002 Address |
F21:119 |
10991 |
D10990 |
DWORD |
%MD21.119 |
DWORD |
Read/Write |
PROFINET Custom Data Record 1003 Address |
RMC75S |
|||||||
F21:0 |
10753 |
D10752 |
REAL |
%MD21.0 |
DINT |
Read Only |
RS-232 Monitor Baud Rate |
F21:1 |
10755 |
D10754 |
REAL |
%MD21.1 |
DWORD |
Read Only |
RS-232 Monitor Configuration Bits |
F21:2 |
10757 |
D10756 |
REAL |
%MD21.2 |
DINT |
Read Only |
RS-232 Monitor Protocol |
F21:3 |
10759 |
D10758 |
REAL |
%MD21.3 |
DINT |
Read Only |
RS-232 Monitor Address |
F21:4 |
10761 |
D10760 |
REAL |
%MD21.4 |
DINT |
Read/Write |
Comm. Serial Baud Rate |
F21:5 |
10763 |
D10762 |
REAL |
%MD21.5 |
DWORD |
Read/Write |
|
F21:6 |
10765 |
D10764 |
REAL |
%MD21.6 |
DINT |
Read/Write |
Comm. Serial Protocol |
F21:7 |
10767 |
D10766 |
REAL |
%MD21.7 |
DINT |
Read/Write |
Comm. Serial Address |
RMC75P |
|||||||
F21:0 |
10753 |
D10752 |
REAL |
%MD21.0 |
DINT |
Read Only |
RS-232 Monitor Baud Rate |
F21:1 |
10755 |
D10754 |
REAL |
%MD21.1 |
DWORD |
Read Only |
RS-232 Monitor Configuration Bits |
F21:2 |
10757 |
D10756 |
REAL |
%MD21.2 |
DINT |
Read Only |
RS-232 Monitor Protocol |
F21:3 |
10759 |
D10758 |
REAL |
%MD21.3 |
DINT |
Read Only |
RS-232 Monitor Address |
F21:4 |
10761 |
D10760 |
REAL |
%MD21.4 |
DINT |
Read Only |
|
F21:5 |
10763 |
D10762 |
- |
%MD21.5 |
- |
- |
Reserved |
F21:6 |
10765 |
D10764 |
DWORD |
%MD21.6 |
DWORD |
Read Only |
See Also