A2 Expansion Module

The 2-input Analog expansion module (A2) is one of the optional expansion modules available for the RMC75 motion controller. This module provides two analog inputs with 16-bit resolution.

The A2 should not be confused with the AP2, which provides analog input with support for pressure control. If you do not require position-pressure/force or control, you do not need the AP2.

Note: Using the A2 module, it is possible to add more analog inputs on the RMC75 than can be assigned to axes. However, it is still possible to view the voltage of the extra analog inputs using the Analog Input Registers. Inputs that are unassigned to axes can have no status bits, error bits, scaling, filtering, etc.

Features

Uses

Part Number

The part number of the A2 module is EXP70-A2.

Specifications

General

Weight

102 g + 19 g (connector)

Analog Interface

Inputs

Two 16-bit differential

Isolation

500 VAC

Overvoltage protection

±40 V

Input ranges

±10 V and 4 20 mA (each channel independently configured)

Broken wire detection

When the input is not connected, internal biasing pulls the input voltage down to its full negative value.

Input impedance

Voltage Input: 5 MΩ

Current Input: 250 Ω  

Input filter slew rate

25 V/ms

Oversampling

8 times per control loop

Offset drift with temperature +10 V (4-20 mA)

0.2 LSB/ºC (1 µA/ºC) typical*

Gain drift with temperature +10V (4-20 mA)

20 ppm/ºC (0.003 %/ºC) typical*

Non-linearity

12 LSB (counts) typical (+10 V range)

Exciter Output

10 VDC ± 2%, 8 mA

  *Max Offset Drift 4.8 µA/ºC, Max Gain Drift 0.009 %/ºC under maximum possible circuit component error amount.

LEDs

Input LED
This LED represents the input and control status for the axis. This bi-color (red/green) LED has the following states:

State

Description

Steady Off

No power or this input is not assigned to an axis.

Steady Green

The axis is either in closed loop control or is a reference axis. The axis is not halted.

Flashing Green

The input is in open loop and the axis is not halted (not possible for reference axes).

Flashing Red

A Closed Loop Halt or External Halt has occurred because an error bit is set (not possible for reference axes). The LED will not turn red due to a halt caused by halt command.

Steady Red

An Open Loop Halt or Direct Output Halt has occurred because an error bit is set (for reference axes, any halt has occurred). The LED will not turn red due to a halt caused by halt command.

 

 

See Also

A2 Wiring | Analog Position Scaling | Analog Velocity Scaling | Analog Acceleration Scaling | Analog Pressure/Force Scaling | Analog Fundamentals