Back

RMC150 Registers, Files 96-103: Plot Status/Configuration Registers

The following files contain the Plot Configuration registers. See the Reading Plots with a Host Controller topic for details on how some of them can be used.

 

f = 96 + n

b= 512 xn

AB

DF1,CSP
Address

Modbus
TCP
,RTU
Address

FINS

Address

External

Data Type

Internal

IEC
Address

Internal
Data Type

Access

Register Name

Plot n

Ff:0

49153 + b

E0_16384 + b

REAL

%MDf.0

DWORD

not directly

ClosedPlot Flags

These bits should not be accessed directly.

0

Reserved (Write Only)

1

Trigger (Write only)

2

Rearm (Write Only)

3

Read Active (Read Only)

4

Trigger Enabled (Read Only)

Ff:1

49155 + b

E0_16386 + b

REAL

%MDf.1

DINT

Read/Write

Plot Samples (e.g. 1000)

Ff:2

49157 + b

E0_16388 + b

REAL

%MDf.2

REAL

Read/Write

Plot Sample Period (seconds)

Ff:3

49159 + b

E0_16390 + b

REAL

%MDf.3

DINT

Read/Write

ClosedPlot Axis Owner

0-15, -1 = none

Ff:4

49161 + b

E0_16392 + b

REAL

%MDf.4

REAL

Read/Write

ClosedPlot Trigger Position

%, 0-100, -1 = auto rearm

Ff:5

49163 + b

E0_16394 + b

REAL

%MDf.5

DWORD

Read/Write

ClosedPlot Trigger Type

0-7

Trigger Type

(0=none, 1=motion command)

8-23

Depends on trigger type.

Motion Commands:

Axis 0-15. If all bits are zero, then use Axis Owner

 

Ff:6

49165 + b

E0_16396 + b

REAL

%MDf.6

-

-

Reserved

Ff:7

49167 + b

E0_16398 + b

REAL

%MDf.7

-

-

Reserved

Ff:8

49169 + b

E0_16400 + b

REAL

%MDf.8

DINT

Read Only

Plot ID

Ff:9

49171 + b

E0_16402 + b

REAL

%MDf.9

DINT

Read Only

ClosedPlot State

0 = not triggered, 1 = capturing, 2 = complete

Ff:10

49173 + b

E0_16404 + b

REAL

%MDf.10

DINT

Read Only

ClosedPlot Captured Samples

Number of plot samples captured. Only applies for Plot State > 0.

Ff:11

49175 + b

E0_16406 + b

REAL

%MDf.11

DINT

Read Only

ClosedPlot Sample 0 Time

Time that first plot sample was captured. In control loops since controller startup (low 24 bits). Only applies for Plot State > 0.

Ff:12

49177 + b

E0_16408 + b

REAL

%MDf.12

DINT

Read Only

ClosedPlot Trigger Time

Time that plot trigger occurred. In control loops since controller startup (low 24 bits). Only applies for Plot State > 0.

Ff:13

49179 + b

E0_16410 + b

REAL

%MDf.13

DINT

Read Only

ClosedPlot Trigger Index

Index of the plot sample at which the plot trigger occurred. Only applies for Plot State > 0.

Ff:14-

15

49181 + b

49183 + b

E0_16412 + b

E0_16414 + b

-

%MDf.14-15

-

-

Reserved

Ff:16-

31

49185 + b

49215 + b

E0_16416 + b

E0_16446 + b

REAL

%MDf.16-31

DWORD

Read/Write

ClosedPlot Data Sets 0-15 Addresses

Files %MDn:16-31 contain the Addresses for plot Data Sets 0-15.

Bits 0-11

Element

Bits 12-23

File

 

See Also

RMC150 Register Map


Send comments on this topic.

Copyright © 2024 Delta Computer Systems, Inc. dba Delta Motion