Back

RMC150 Registers, Files 112-143: Static Plot Upload Area Registers

All Static Plot Upload Area Registers are Read Only.  See the Reading Plots with a Host Controller topic for details on how to use them.

The data types of the plot data is determined by the plotted registers.

Tip:
For the DF1/CSP addressing format, all 'F' type registers (32-bit floating point) can also be read as 'L' type (32-bit word) registers. This is very useful when reading plot data of DWORD or DINT data types.

 

Note:
When communicating via a protocol that uses DF1 addressing, samples 0-4095 from each plot can be addressed, if the host controller allows it. For example, F112:4095 addresses sample 4095 of plot 0, data set 0.
Other protocols can only address the first 256 samples, as indicated below.

 

AB

DF1,CSP
Address

Modbus
TCP
,RTU
Address

(max 256 registers)

FINS

Address
(max 256 registers)

Internal

IEC
Address

Register Name

Plot 0

F112:0-4095

57345-57855

E0_24576-E0_25086

%MD112.0-4095

Plot 0, Data Set 0, Samples 0-4095

F113:0-4095

57857-58367

E0_25088-E0_25598

%MD113.0-4095

Plot 0, Data Set 1, Samples 0-4095

F114:0-4095

58369-58879

E0_25600-E0_26110

%MD114.0-4095

Plot 0, Data Set 2, Samples 0-4095

F115:0-4095

58881-59391

E0_26112-E0_26622

%MD115.0-4095

Plot 0, Data Set 3, Samples 0-4095

Plot 1

F116:0-4095

59393-59903

E0_26624-E0_27134

%MD116.0-4095

Plot 1, Data Set 1, Samples 0-4095

F117:0-4095

59905-60415

E0_27136-E0_27646

%MD117.0-4095

Plot 1, Data Set 2, Samples 0-4095

F118:0-4095

60417-60927

E0_27648-E0_28158

%MD118.0-4095

Plot 1, Data Set 3, Samples 0-4095

F119:0-4095

60929-61439

E0_28160-E0_28670

%MD119.0-4095

Plot 1, Data Set 4, Samples 0-4095

Plot 2

F120:0-4095

61441-61951

E0_28672-E0_29182

%MD120.0-4095

Plot 2, Data Set 1, Samples 0-4095

F121:0-4095

61953-62463

E0_29184-E0_29694

%MD121.0-4095

Plot 2, Data Set 2, Samples 0-4095

F122:0-4095

62465-62975

E0_29696-E0_30206

%MD122.0-4095

Plot 2, Data Set 3, Samples 0-4095

F123:0-4095

62977-63487

E0_30208-E0_30718

%MD123.0-4095

Plot 2, Data Set 4, Samples 0-4095

Plot 3

F124:0-4095

63489-63999

E0_30720-E0_31230

%MD124.0-4095

Plot 3, Data Set 1, Samples 0-4095

F125:0-4095

64001-64511

E0_31232-E0_31742

%MD125.0-4095

Plot 3, Data Set 2, Samples 0-4095

F126:0-4095

64513-65023

E0_31744-E0_32254

%MD126.0-4095

Plot 3, Data Set 3, Samples 0-4095

F127:0-4095

65025-65535

E0_32256-E0_32766

%MD127.0-4095

Plot 3, Data Set 4, Samples 0-4095

Plot 4

F128:0-4095

65537-66047

E1_00000-E1_00510

%MD128.0-4095

Plot 4, Data Set 1, Samples 0-4095

F129:0-4095

66049-66559

E1_00512-E1_01022

%MD129.0-4095

Plot 4, Data Set 2, Samples 0-4095

F130:0-4095

66561-67071

E1_01024-E1_01534

%MD130.0-4095

Plot 4, Data Set 3, Samples 0-4095

F131:0-4095

67073-67583

E1_01536-E1_02046

%MD131.0-4095

Plot 4, Data Set 4, Samples 0-4095

Plot 5

F132:0-4095

67585-68095

E1_02048-E1_02558

%MD132.0-4095

Plot 5, Data Set 1, Samples 0-4095

F133:0-4095

68097-68607

E1_02560-E1_03070

%MD133.0-4095

Plot 5, Data Set 2, Samples 0-4095

F134:0-4095

68609-69119

E1_03072-E1_03582

%MD134.0-4095

Plot 5, Data Set 3, Samples 0-4095

F135:0-4095

69121-69631

E1_03584-E1_04094

%MD135.0-4095

Plot 5, Data Set 4, Samples 0-4095

Plot 6

F136:0-4095

69633-70143

E1_04096-E1_04606

%MD136.0-4095

Plot 6, Data Set 1, Samples 0-4095

F137:0-4095

70145-70655

E1_04608-E1_05118

%MD137.0-4095

Plot 6, Data Set 2, Samples 0-4095

F138:0-4095

70657-71167

E1_05120-E1_05630

%MD138.0-4095

Plot 6, Data Set 3, Samples 0-4095

F139:0-4095

71169-71679

E1_05632-E1_06142

%MD139.0-4095

Plot 6, Data Set 4, Samples 0-4095

Plot 7

F140:0-4095

71681-72191

E1_06144-E1_06654

%MD140.0-4095

Plot 7, Data Set 1, Samples 0-4095

F141:0-4095

72193-72703

E1_06656-E1_07166

%MD141.0-4095

Plot 7, Data Set 2, Samples 0-4095

F142:0-4095

72705-73215

E1_07168-E1_07678

%MD142.0-4095

Plot 7, Data Set 3, Samples 0-4095

F143:0-4095

73217-73727

E1_07680-E1_08190

%MD143.0-4095

Plot 7, Data Set 4, Samples 0-4095

 

See Also

RMC150 Register Map


Send comments on this topic.

Copyright © 2024 Delta Computer Systems, Inc. dba Delta Motion