RMC150 Registers, Files 104-111: Dynamic Plot Upload Area Registers

The following files contain the Dynamic Plot Upload Area registers. See the Reading Plots with a Host Controller topic for details on how to use them.

Tip:
For the DF1/CSP addressing format, all 'F' type registers (32-bit floating point) can also be read as 'L' type (32-bit word) registers. This is very useful when reading data of DWORD or DINT external data types.

 

Note:
When communicating via a protocol that uses DF1 addressing, the Plot Data can be accessed with registers 5-4095, if the host controller allows it. Other protocols can only address Plot Data registers 5-255, as indicated below.

 

AB

DF1,CSP
Address

Modbus
TCP
,RTU
Address

FINS

Address

External

Data Type

Internal

IEC
Address

Internal
Data Type

Access

Register Name

Plot 0

F104:0

53249

E0_20480

DINT

%MD104.0

UDINT

Read/Write

Plot 0 Upload Mode/Status

F104:1

53251

E0_20482

DINT

%MD104.1

UDINT

Read/Write

Plot 0 Requested Read Samples

F104:2

53253

E0_20484

DINT

%MD104.2

UDINT

Read/Write

Plot 0 Current Index

F104:3

53255

E0_20486

DINT

%MD104.3

UDINT

Read Only

Plot 0 ID

F104:4

53257

E0_20488

DINT

%MD104.4

UDINT

Read Only

Plot 0 Samples Uploaded

F104:5-

255

53259-

53759

E0_20490-

E0_20990

*

%MD104.5-

255

*

Read Only

Plot 0 Data

Plot 1

F105:0

53761

E0_20992

DINT

%MD105.0

UDINT

Read/Write

Plot 1 Upload Mode/Status

F105:1

53763

E0_20994

DINT

%MD105.1

UDINT

Read/Write

Plot 1 Requested Read Samples

F105:2

53765

E0_20996

DINT

%MD105.2

UDINT

Read/Write

Plot 1 Current Index

F105:3

53767

E0_20998

DINT

%MD105.3

UDINT

Read Only

Plot 1 ID

F105:4

53769

E0_21000

DINT

%MD105.4

UDINT

Read Only

Plot 1 Samples Uploaded

F105:5-

255

53771-

54271

E0_21002-

E0_21502

*

%MD105.5-

255

*

Read Only

Plot 1 Data

Plot 2

F106:0

54273

E0_21504

DINT

%MD106.0

UDINT

Read/Write

Plot 2 Upload Mode/Status

F106:1

54275

E0_21506

DINT

%MD106.1

UDINT

Read/Write

Plot 2 Requested Read Samples

F106:2

54277

E0_21508

DINT

%MD106.2

UDINT

Read/Write

Plot 2 Current Index

F106:3

54279

E0_21510

DINT

%MD106.3

UDINT

Read Only

Plot 2 ID

F106:4

54281

E0_21512

DINT

%MD106.4

UDINT

Read Only

Plot 2 Samples Uploaded

F106:5-

255

54283-

54783

E0_21514-

E0_22014

*

%MD106.5-

255

*

Read Only

Plot 2 Data

Plot 3

F107:0

54785

E0_22016

DINT

%MD107.0

UDINT

Read/Write

Plot 3 Upload Mode/Status

F107:1

54787

E0_22018

DINT

%MD107.1

UDINT

Read/Write

Plot 3 Requested Read Samples

F107:2

54789

E0_22020

DINT

%MD107.2

UDINT

Read/Write

Plot 3 Current Index

F107:3

54791

E0_22022

DINT

%MD107.3

UDINT

Read Only

Plot 3 ID

F107:4

54793

E0_22024

DINT

%MD107.4

UDINT

Read Only

Plot 3 Samples Uploaded

F107:5-

255

54795-

55295

E0_22026-

E0_22526

*

%MD107.5-

255

*

Read Only

Plot 3 Data

Plot 4

F108:0

55297

E0_22528

DINT

%MD108.0

UDINT

Read/Write

Plot 4 Upload Mode/Status

F108:1

55299

E0_22530

DINT

%MD108.1

UDINT

Read/Write

Plot 4 Requested Read Samples

F108:2

55301

E0_22532

DINT

%MD108.2

UDINT

Read/Write

Plot 4 Current Index

F108:3

55303

E0_22534

DINT

%MD108.3

UDINT

Read Only

Plot 4 ID

F108:4

55305

E0_22536

DINT

%MD108.4

UDINT

Read Only

Plot 4 Samples Uploaded

F108:5-

255

55307-

55807

E0_22538-

E0_23038

*

%MD108.5-

255

*

Read Only

Plot 4 Data

Plot 5

F109:0

55809

E0_23040

DINT

%MD109.0

UDINT

Read/Write

Plot 5 Upload Mode/Status

F109:1

55811

E0_23042

DINT

%MD109.1

UDINT

Read/Write

Plot 5 Requested Read Samples

F109:2

55813

E0_23044

DINT

%MD109.2

UDINT

Read/Write

Plot 5 Current Index

F109:3

55815

E0_23046

DINT

%MD109.3

UDINT

Read Only

Plot 5 ID

F109:4

55817

E0_23048

DINT

%MD109.4

UDINT

Read Only

Plot 5 Samples Uploaded

F109:5-

255

55819-

56319

E0_23050-

E0_23550

*

%MD109.5-

255

*

Read Only

Plot 5 Data

Plot 6

F110:0

56321

E0_23552

DINT

%MD110.0

UDINT

Read/Write

Plot 6 Upload Mode/Status

F110:1

56323

E0_23554

DINT

%MD110.1

UDINT

Read/Write

Plot 6 Requested Read Samples

F110:2

56325

E0_23556

DINT

%MD110.2

UDINT

Read/Write

Plot 6 Current Index

F110:3

56327

E0_23558

DINT

%MD110.3

UDINT

Read Only

Plot 6 ID

F110:4

56329

E0_23560

DINT

%MD110.4

UDINT

Read Only

Plot 6 Samples Uploaded

F110:5-

255

56331-

56831

E0_23562-

E0_24062

*

%MD110.5-

255

*

Read Only

Plot 6 Data

Plot 7

F111:0

56833

E0_24064

DINT

%MD111.0

UDINT

Read/Write

Plot 7 Upload Mode/Status

F111:1

56835

E0_24066

DINT

%MD111.1

UDINT

Read/Write

Plot 7 Requested Read Samples

F111:2

56837

E0_24068

DINT

%MD111.2

UDINT

Read/Write

Plot 7 Current Index

F111:3

56839

E0_24070

DINT

%MD111.3

UDINT

Read Only

Plot 7 ID

F111:4

56841

E0_24072

DINT

%MD111.4

UDINT

Read Only

Plot 7 Samples Uploaded

F111:5-

255

56843-

57343

E0_24074-

E0_24574

*

%MD111.5-

255

*

Read Only

Plot 7 Data

*The data types of the Plot Data are determined by the plotted registers.

 

See Also

RMC150 Register Map


Send comments on this topic.