RMC75 Registers, Files 56-59, 64-67, 68: Variables Registers

All variable registers are Read/Write.

Tip:
For the DF1/CSP addressing format, all 'F' type registers (32-bit floating point) can also be read as 'L' type (32-bit word) registers. This is very useful when reading variables defined as DWORD or DINT data types.

 

AB

DF1,CSP
Address

Modbus
TCP
,RTU
Address

FINS

Address

External

Data Type

Internal

IEC
Address

Internal
Data Type

Register Name

Variables - Current Values

F56:0-255

28673-

29183

D28672-

D29182

*

%MD56.0-255

*

Variables 0-255 - Current Values

F57:0-255

29185-

29695

D29184-

D29694

*

%MD57.0-255

*

Variables 256-511 - Current Values

F58:0-255

29697-

30207

D29696-

D30206

*

%MD58.0-255

*

Variables 512-767 - Current Values

F59:0-255

30209-

30719

D30208-

D30718

*

%MD59.0-255

*

Variables 768-1023 - Current Values

Variables - Initial Values

F64:0-255

32769-

33279

D32768-

D33278

*

%MD64.0-255

*

Variables 0-255 - Initial Values

F65:0-255

33281-

33791

D33280-

D33790

*

%MD65.0-255

*

Variables 256-511 - Initial Values

F66:0-255

33793-

34303

D33792-

D34302

*

%MD66.0-255

*

Variables 512-767 - Initial Values

F67:0-255

34305-

34815

D34304-

D34814

*

%MD67.0-255

*

Variables 768-1023 - Initial Values

Variables - Attributes

F68:0-255

34817-

35327

D34816-

D35326

DWORD

%MD68.0-255

DWORD

Variables 0-1023 - Attributes (4 variables per register)

* The Data Types of the variables are specified by the user when defining a variable in the Variable Table.

Allen-Bradley DF1 and CSP

Where allowed by the host controller's communications, all the variables can also be addressed as F56:n, up to n = 1023.

Modbus/TCP and /RTU

The address of the current value of variable n is 28673 + 2 x n.

FINS

The address of the current value of variable n is D28672 + 2 x n.

 

See Also

RMC75 Register Map Overview | Variable Attributes