RMC75 Registers, Files 40-47: Dynamic Plot Upload Area

The following files contain the Dynamic Plot Upload Area registers. See the Reading Plots with a Host Controller topic for details on how to use them.

Tip:
For the DF1/CSP addressing format, all 'F' type registers (32-bit floating point) can also be read as 'L' type (32-bit word) registers. This is very useful when reading data of DWORD or DINT external data types.

 

Note:
When communicating via a protocol that uses DF1 addressing, the Plot Data can be accessed with registers 5-4095, if the host controller allows it.
Other protocols can only address Plot Data registers 5-255, as indicated below.

 

AB

DF1,CSP
Address

Modbus
TCP
,RTU
Address

FINS

Address

External

Data Type

Internal

IEC
Address

Internal
Data Type

Access

Register Name

Plot 0

F40:0

20481

D20480

DINT

%MD40.0

UDINT

Read/Write

Plot 0 Flags

F40:1

20483

D20482

DINT

%MD40.1

UDINT

Read/Write

Plot 0 Requested Read Samples

F40:2

20485

D20484

DINT

%MD40.2

UDINT

Read/Write

Plot 0 Current Index

F40:3

20487

D20486

DINT

%MD40.3

UDINT

Read Only

Plot 0 ID

F40:4

20489

D20488

DINT

%MD40.4

UDINT

Read Only

Plot 0 Samples Uploaded

F40:5-255

20491-20991

D20490-

D20990

*

%MD40.5-255

*

Read Only

Plot 0 Data

Plot 1

F41:0

20993

D20992

DINT

%MD41.0

UDINT

Read/Write

Plot 1 Flags

F41:1

20995

D20994

DINT

%MD41.1

UDINT

Read/Write

Plot 1 Requested Read Samples

F41:2

20997

D20996

DINT

%MD41.2

UDINT

Read/Write

Plot 1 Current Index

F41:3

20999

D20998

DINT

%MD41.3

UDINT

Read Only

Plot 1 ID

F41:4

21001

D21000

DINT

%MD41.4

UDINT

Read Only

Plot 1 Samples Uploaded

F41:5-255

21003-21503

D21002-

D21502

*

%MD41.5-255

*

Read Only

Plot 1 Data

Plot 2

F42:0

21505

D21504

DINT

%MD42.0

UDINT

Read/Write

Plot 2 Flags

F42:1

21507

D21506

DINT

%MD42.1

UDINT

Read/Write

Plot 2 Requested Read Samples

F42:2

21509

D21508

DINT

%MD42.2

UDINT

Read/Write

Plot 2 Current Index

F42:3

21511

D21510

DINT

%MD42.3

UDINT

Read Only

Plot 2 ID

F42:4

21513

D21512

DINT

%MD42.4

UDINT

Read Only

Plot 2 Samples Uploaded

F42:5-255

21515-22015

D21514

D22014

*

%MD42.5-255

*

Read Only

Plot 2 Data

Plot 3

F43:0

22017

D22016

DINT

%MD43.0

UDINT

Read/Write

Plot 3 Flags

F43:1

22019

D22018

DINT

%MD43.1

UDINT

Read/Write

Plot 3 Requested Read Samples

F43:2

22021

D22020

DINT

%MD43.2

UDINT

Read/Write

Plot 3 Current Index

F43:3

22023

D22022

DINT

%MD43.3

UDINT

Read Only

Plot 3 ID

F43:4

22025

D22024

DINT

%MD43.4

UDINT

Read Only

Plot 3 Samples Uploaded

F43:5-255

22027-22527

D22026-

D22526

*

%MD43.5-255

*

Read Only

Plot 3 Data

Plot 4

F44:0

22529

D22528

DINT

%MD44.0

UDINT

Read/Write

Plot 4 Flags

F44:1

22531

D22530

DINT

%MD44.1

UDINT

Read/Write

Plot 4 Requested Read Samples

F44:2

22533

D22532

DINT

%MD44.2

UDINT

Read/Write

Plot 4 Current Index

F44:3

22535

D22534

DINT

%MD44.3

UDINT

Read Only

Plot 4 ID

F44:4

22537

D22536

DINT

%MD44.4

UDINT

Read Only

Plot 4 Samples Uploaded

F44:5-255

22539-23039

D22538-

D23038

*

%MD44.5-255

*

Read Only

Plot 4 Data

Plot 5

F45:0

23041

D23040

DINT

%MD45.0

UDINT

Read/Write

Plot 5 Flags

F45:1

23043

D23042

DINT

%MD45.1

UDINT

Read/Write

Plot 5 Requested Read Samples

F45:2

23045

D23044

DINT

%MD45.2

UDINT

Read/Write

Plot 5 Current Index

F45:3

23047

D23046

DINT

%MD45.3

UDINT

Read Only

Plot 5 ID

F45:4

23049

D23048

DINT

%MD45.4

UDINT

Read Only

Plot 5 Samples Uploaded

F45:5-255

23051-23551

D23050

D23550

*

%MD45.5-255

*

Read Only

Plot 5 Data

Plot 6

F46:0

23553

D23552

DINT

%MD46.0

UDINT

Read/Write

Plot 6 Flags

F46:1

23555

D23554

DINT

%MD46.1

UDINT

Read/Write

Plot 6 Requested Read Samples

F46:2

23557

D23556

DINT

%MD46.2

UDINT

Read/Write

Plot 6 Current Index

F46:3

23559

D23558

DINT

%MD46.3

UDINT

Read Only

Plot 6 ID

F46:4

23561

D23560

DINT

%MD46.4

UDINT

Read Only

Plot 6 Samples Uploaded

F46:5-255

23563-24063

D23562-

D24062

*

%MD46.5-255

*

Read Only

Plot 6 Data

Plot 7

F47:0

24065

D24064

DINT

%MD47.0

UDINT

Read/Write

Plot 7 Flags

F47:1

24067

D24066

DINT

%MD47.1

UDINT

Read/Write

Plot 7 Requested Read Samples

F47:2

24069

D24068

DINT

%MD47.2

UDINT

Read/Write

Plot 7 Current Index

F47:3

24071

D24070

DINT

%MD47.3

UDINT

Read Only

Plot 7 ID

F47:4

24073

D24072

DINT

%MD47.4

UDINT

Read Only

Plot 7 Samples Uploaded

F47:5-255

24075-24575

D24074-

D24574

*

%MD47.5-255

*

Read Only

Plot 7 Data

*The Data Types of the Plot Data are determined by the plotted registers.

 