RMC75 Registers, Files 32-39: Plot Status/Configuration Registers
The following files contain the Plot Configuration registers. See the Reading Plots with a Host Controller topic for details on how some of them can be used.
n = plot # (0-7)
f = 32 + n
b= 512 xn
AB |
Address |
External |
Internal IEC |
Internal |
Access |
Register Name |
|
---|---|---|---|---|---|---|---|
Plot 0 |
|||||||
Ff:0 |
16385 + b |
D16384 + b |
REAL |
%MDf.0 |
DWORD |
not directly |
|
Ff:1 |
16387 + b |
D16386 + b |
REAL |
%MDf.1 |
DINT |
Read/Write |
Plot Samples (e.g. 1000) |
Ff:2 |
16389 + b |
D16388 + b |
REAL |
%MDf.2 |
REAL |
Read/Write |
Plot Sample Period (seconds) |
Ff:3 |
16391 + b |
D16390 + b |
REAL |
%MDf.3 |
DINT |
Read/Write |
|
Ff:4 |
16393 + b |
D16392 + b |
REAL |
%MDf.4 |
REAL |
Read/Write |
|
Ff:5 |
16395 + b |
D16394 + b |
REAL |
%MDf.5 |
DWORD |
Read/Write |
|
Ff:6 |
16397 + b |
D16396 + b |
REAL |
%MDf.6 |
- |
- |
Reserved |
Ff:7 |
16399 + b |
D16398 + b |
REAL |
%MDf.7 |
- |
- |
Reserved |
Ff:8 |
16401 + b |
D16400 + b |
REAL |
%MDf.8 |
DINT |
Read Only |
Plot ID |
Ff:9 |
16403 + b |
D16402 + b |
REAL |
%MDf.9 |
DINT |
Read Only |
|
Ff:10 |
16405 + b |
D16404 + b |
REAL |
%MDf.10 |
DINT |
Read Only |
|
Ff:11 |
16407 + b |
D16406 + b |
REAL |
%MDf.11 |
DINT |
Read Only |
|
Ff:12 |
16409 + b |
D16408 + b |
REAL |
%MDf.12 |
DINT |
Read Only |
|
Ff:13 |
16411 + b |
D16410 + b |
REAL |
%MDf.13 |
DINT |
Read Only |
|
Ff:14-15 |
16413 + b to 16415 + b |
D16412 + b D16414 + b |
- |
%MDf.14-15 |
- |
- |
Reserved |
Ff:16-31 |
16417 + b to 16447 + b |
D16416 + b D16446 + b |
REAL |
%MDf.16-31 |
DWORD |
Read/Write |
See Also
Copyright © 2024 Delta Computer Systems, Inc. dba Delta Motion