Back

RMC75 Registers, Files 32-39: Plot Status/Configuration Registers

The following files contain the Plot Configuration registers. See the Reading Plots with a Host Controller topic for details on how some of them can be used.

n = plot # (0-7)

f = 32 + n

b= 512 xn

AB

DF1,CSP
Address

Modbus
TCP
,RTU
Address

FINS

Address

External

Data Type

Internal

IEC
Address

Internal
Data Type

Access

Register Name

Plot 0

Ff:0

16385 + b

D16384 + b

REAL

%MDf.0

DWORD

not directly

ClosedPlot Flags

These bits should not be accessed directly.

0

Reserved (Write Only)

1

Trigger (Write only)

2

Rearm (Write Only)

3

Read Active (Read Only)

4

Trigger Enabled (Read Only)

Ff:1

16387 + b

D16386 + b

REAL

%MDf.1

DINT

Read/Write

Plot Samples (e.g. 1000)

Ff:2

16389 + b

D16388 + b

REAL

%MDf.2

REAL

Read/Write

Plot Sample Period (seconds)

Ff:3

16391 + b

D16390 + b

REAL

%MDf.3

DINT

Read/Write

ClosedPlot Axis Owner

0-3, -1 = none

Ff:4

16393 + b

D16392 + b

REAL

%MDf.4

REAL

Read/Write

ClosedPlot Trigger Position

%, 0-100, -1 = auto rearm

Ff:5

16395 + b

D16394 + b

REAL

%MDf.5

DWORD

Read/Write

ClosedPlot Trigger Type

0-7

Trigger Type

(0=none, 1=motion command)

8-23

Depends on trigger type

Motion Commands:

8-11

Axis 0-3 bits, if all zero, then use Axis Owner

12-23

Reserved

 

Ff:6

16397 + b

D16396 + b

REAL

%MDf.6

-

-

Reserved

Ff:7

16399 + b

D16398 + b

REAL

%MDf.7

-

-

Reserved

Ff:8

16401 + b

D16400 + b

REAL

%MDf.8

DINT

Read Only

Plot ID

Ff:9

16403 + b

D16402 + b

REAL

%MDf.9

DINT

Read Only

ClosedPlot State

0 = not triggered, 1 = capturing, 2 = complete

Ff:10

16405 + b

D16404 + b

REAL

%MDf.10

DINT

Read Only

ClosedPlot Captured Samples

Number of plot samples captured. Only applies for Plot State > 0.

Ff:11

16407 + b

D16406 + b

REAL

%MDf.11

DINT

Read Only

ClosedPlot Sample 0 Time

Time that first plot sample was captured. In control loops since controller startup (low 24 bits). Only applies for Plot State > 0.

Ff:12

16409 + b

D16408 + b

REAL

%MDf.12

DINT

Read Only

ClosedPlot Trigger Time

Time that plot trigger occurred. In control loops since controller startup (low 24 bits). Only applies for Plot State > 0.

Ff:13

16411 + b

D16410 + b

REAL

%MDf.13

DINT

Read Only

ClosedPlot Trigger Index

Index of the plot sample at which the plot trigger occurred. Only applies for Plot State > 0.

Ff:14-15

16413 + b to

16415 + b

D16412 + b

D16414 + b

-

%MDf.14-15

-

-

Reserved

Ff:16-31

16417 + b to

16447 + b

D16416 + b

D16446 + b

REAL

%MDf.16-31

DWORD

Read/Write

ClosedPlot Data Sets 0-15 Addresses

Files %MDn:16-31 contain the Addresses for plot Data Sets 0-15.

Bits 0-11

Element

Bits 12-23

File

 

See Also

RMC75 Register Map Overview


Send comments on this topic.