RMC75 Registers, File 31: Plot Layout

The following files contain the Plot Layout registers.

Tip:
For the DF1/CSP addressing format, all 'F' type registers (32-bit floating point) can also be read as 'L' type (32-bit word) registers. This is very useful when reading data of DWORD or DINT external data types.

 

AB

DF1,CSP
Address

Modbus
TCP
,RTU
Address

FINS

Address

External

Data Type

Internal

IEC
Address

Internal
Data Type

Access

Register Name

F31:0

15873

D15872

REAL

%MD31.0

UDINT

Read/Write

ClosedCurrent Plot Layout

This register indicates the current plot allocation.

Bit

Description

0-7

Plots (1-8)

8-15

Sample Sets per Plot (1-16)

16-23

Reserved

F31:1

15875

D15874

REAL

%MD31.1

UDINT

Read Only

ClosedMaximum Plots (8)

This read-only value indicates how many plots can be defined at once.

F31:2

15877

D15876

REAL

%MD31.2

UDINT

Read Only

ClosedMaximum Samples (16)

This read-only value indicates how many samples sets can be captured simultaneously per plot.

F31:3

15879

D15878

REAL

%MD31.3

UDINT

Read Only

ClosedMaximum Samples at Once (128)

This read-only value indicates how many total different samples can be allocated across all plots.

F31:4

15881

D15880

REAL

%MD31.4

UDINT

Read Only

ClosedMaximum Elements

RMC75S/P: 32,768

RMC75E: 12,583,912

Note: Prior to 2.00 firmware, the RMC75E is limited to 32,768 elements. Prior to 1.02 Loader, the RMC75E is limited to 4,194,304.

This read-only value indicates how many total data points can be captured. This is spread out among the number of allocated plots and samples per plot.

 

F31:5

15883

D15882

-

%MD31.5

UDINT

-

Reserved

F31:6

15885

D15884

-

%MD31.6

UDINT

-

Reserved

F31:7

15887

D15886

-

%MD31.7

UDINT

-

Reserved

 

See Also

RMC75 Register Map Overview