Back

RMC75 Registers, File 30:  Image Upload/Download Area

See the Controller Image Upload/Download topic for details.

Tip:
For the DF1/CSP addressing format, all 'F' type registers (32-bit floating point) can also be read as 'L' type (32-bit word) registers. This is very useful when reading registers with DWORD or DINT external data types.

 

AB

DF1,CSP
Address

Modbus
TCP
,RTU
Address

FINS

Address

External

Data Type

Internal

IEC
Address

Internal
Data Type

Access

Register Name

F30:0

15361

D15360

DINT

%MD30.0

DINT

Write Only

Image Area Command

F30:1

15363

D15362

DINT

%MD30.1

DINT

Read Only

Image Area State

F30:2

15365

D15364

DINT

%MD30.2

DINT

Read Only

Image Size

F30:3

15367

D15366

DINT

%MD30.3

DINT

Read/Write

Current Index

F30:4

:

F30:4095

15369-

15871

(252 items)

D15368-

D15870

(252 items)

DINT[252]

or

DINT[4092]

%MD30.4

:

%MD30.4095

DINT[252]

or

DINT[4092]

Read/Write

Image Data

 

See Also

RMC75 Register Map Overview | Controller Image Upload/Download


Send comments on this topic.

Copyright © 2024 Delta Computer Systems, Inc. dba Delta Motion