Back

RMC75 Registers, File 20: Controller Status/Parameters

AB

DF1,CSP
Address

Modbus
TCP
,RTU
Address

FINS

Address

External

Data Type

Internal

IEC
Address

Internal
Data Type

Access

Register Name

F20:0

10241

D10240

REAL

%MD20.0

REAL

Read Only

Loop Time, Set (sec)

F20:1

10243

D10242

REAL

%MD20.1

REAL

none

Loop Time, Requested (sec)

F20:2

10245

D10244

REAL

%MD20.2

REAL

Read Only

Loop Time Used, Last (sec)

F20:3

10247

D10246

REAL

%MD20.3

REAL

Read/Write

Loop Time Used, Maximum (sec)

F20:4

10249

D10248

REAL

%MD20.4

DINT

Read/Write

ClosedNumber of Tasks Allocated

0-4 (default = 2)

F20:5

10251

D10250

REAL

%MD20.5

DINT

Read/Write

ClosedProgram Triggers Task Enabled?

0=false, 1= true (default = 1)

F20:6

10253

D10252

REAL

%MD20.6

DWORD

Read/Write

ClosedStop All Tasks on Any Axis Halt?

0=false, 1= true (default = 1)

F20:7

10255

D10254

REAL

%MD20.7

DWORD

Read Only

Controller Status Bits

F20:8

10257

D10256

REAL

%MD20.8

DINT

Read/Write

ClosedStartup Mode

0=PROGRAM, 1-RUN (default = 0)

F20:9

10259

D10258

REAL

%MD20.9

DINT

Read/Write

ClosedRUN/PROGRAM Input

0=none, 1-64=%IX(n-1), 256+a=Axis a Fault Input)

F20:10

10261

D10260

REAL

%MD20.10

REAL

Read Only

Time Gear Master

F20:11

10263

D10262

DINT

%MD20.11

DINT

Read Only

Time, 16th Milliseconds

F20:12

10265

D10264

DINT

%MD20.12

DINT

Read Only

Time, Seconds

F20:13

10267

D10266

DINT

%MD20.13

DINT

Read Only

Time, Milliseconds

F20:14

10269

D10268

DINT

%MD20.14

DINT

Read Only

Time, Microseconds

F20:15

10271

D10270

DINT

%MD20.15

DINT

Read Only

Time, Nanoseconds

F20:16-31

10273-10303

D10272-

D10302

DWORD

%MD20.16-31

DWORD

Read/Write

ClosedController Name

Each 32-bit register holds 2 UTF-16 characters. The MSW is the first and the LSW is the second. For example, 0x004D0061 is ‘Ma’.

F20:32

10305

D10304

DWORD

%MD20.32

DWORD

Read/Write

Controller Configuration Bits

F20:33

10307

D10306

DINT

%MD20.33

DINT

Read Only

Time, Loop Ticks

F20:34

10309

D10308

REAL

%MD20.34

REAL

Read Only

Loop Time Used, Total (µs)

F20:35

10311

D10310

REAL

%MD20.35

REAL

Read Only

Loop Time Used, Axes (µs)

F20:36

10313

D10312

REAL

%MD20.36

REAL

Read Only

Loop Time Used, Programs (µs)

F20:37

10315

D10314

REAL

%MD20.37

REAL

Read Only

Loop Time Used, Plots (µs)

F20:38

10317

D10316

REAL

%MD20.38

REAL

Read Only

Loop Time Used, Comm (µs)

F20:39

10319

D10318

REAL

%MD20.39

REAL

Read Only

Loop Time Used, Overhead (µs)

 

See Also

RMC75 Register Map Overview