Supported Axes: |
See the Commands Overview topic for basic command information and how to issue commands from PLCs, HMIs, etc.
Command Parameters
# |
Parameter Description |
Range |
1 |
Registration Number |
0 or 1 |
Description
This command disarms the specified registration, if it was armed. This command clears the corresponding Registration Armed status bit (Registration 0 Armed and Registration 1 Armed).
For details on registration, see the Registration topic.
See Also
List of Commands | Commands Overview | Registration | Arm Registration (52) Command