Command: Disarm Event Timer (106)

Supported Axes:

All

Firmware Limitations:

RMC75/150: n/a

RMC200 CPU: 1.06.0 and newer

RMC200 D24: 1.04A and newer

 

See the Commands Overview topic for basic command information and how to issue commands from PLCs, HMIs, etc.

Command Parameters

#

Parameter Description

Range

1

Module Slot

The number of the slot that contains the module with the high-speed input to be used for event timing.

The first I/O module slot number on the RMC200 is slot 2.

A valid integer slot number from 2 to the maximum number of slots in the base.

2

Event Timer
The event timer number on the module. This is the internal software resource for the timer. See Event Timers for details.

D24: 0-3

 

Description

This command disarms a previously armed Event Timer. See Event Timers for details.

 

See Also

Event Timers | Arm Event Timer (105)


Send comments on this topic.

Copyright © 2024 Delta Computer Systems, Inc. dba Delta Motion