Analog Transducer LED Indicators

Only the 16-bit analog modules have LED indicators. They correspond to the operational status of channels 0 and 2 when either is used in position mode.

LED Action

Axis Status

Off

Channel is not configured as position control (it is either a pressure or force axis)

Continuous Red

The following error has occurred:

No Transducer

Alternating Red/Green

The above error has not occurred, and one or more of the below errors have occurred and are enabled in the Auto Stop:

Transducer Noise

Transducer Overflow

Overdrive Error

Parameter Error

Position Overflow

Integrator Windup

Following Error

Continuous Green

Status good. None of the above are true.

 

Note: Prior to RMC100 CPU firmware dated 19991216, the Auto Stop parameter was not used in determining the LED states. Therefore, the only way to keep the LED from showing red was to clear the error.

 

Note: Prior to RMC100 CPU firmware dated 20020718, the Transducer Noise and Transducer Overflow errors were not maskable through the Auto Stop parameter, and therefore caused the LED to be solid red.

 