The Point Count register in the Spline Download Area was given an invalid value or was not set before downloading Spline Points. For details on this register see Downloading Splines to the RMC. This register cannot be below 2 or above the point limit per axis.
The point limits depend on the number of spline-capable axes in the RMC. All axes and channels listed by RMCWin as a separate column are spline-capable axes except auxiliary pressure or differential force channels.
The following chart lists the number of points allowed on a given axis depending on the number of spline-capable axes:
Axes |
Point Limit |
2 |
1023 |
3-4 |
511 |
5-8 |
255 |
Copyright (c) 1997-2015 by Delta Computer Systems, Inc.