Dead band eliminator out of range

This parameter error indicates that the DEAD BAND ELIMINATOR parameter was set to a value greater than ±2000. This maximum prevents a dead band of greater than 2 volts. If a valve still does not work to satisfaction with this large of a dead band, then the valve is most like not appropriate for the job. Refer to Hydraulic System Problems for details.

 