The PROFIBUS module for the RMC150 provides PROFIBUS communications. Notice that since the RMC150E CPU has built-in Ethernet, it is possible to communicate via Ethernet and PROFIBUS simultaneously.
For details on setting up and using PROFIBUS, see the PROFIBUS Overview topic.
Features
PROFIBUS-DP
1 Comm Status LED
Standard PROFIBUS-DP DB-9 Connector
Part Number
The part number of the PROFIBUS module is -PROFI. The PROFIBUS module fits only in the left-most slot of the RMC backplane.
For example, RMC150E-S1-PROFI is an RMC150E with an SSI module and a PROFIBUS module. RMC150E-S3-Q1-PROFI is an RMC150E with three SSI modules, one Quadrature module, and a PROFIBUS module.
Specifications
For general specifications on the RMC150, see the RMC150 Overview topic.
General |
|
Weight |
88 g |
PROFIBUS-DP Interface |
|
Data Rate |
9.6 kbaud up to 12 Mbaud |
Isolation |
2500 VAC |
|
0x0AC6 |
Features Supported |
Sync Mode, Freeze Mode, Auto-baud rate detect |
Valid Station Addresses |
0-126 (set by software or Set Slave Address function) |
Connector |
Standard PROFIBUS-DP DB-9 (use termination in cable connectors as per PROFIBUS specification) |
LEDS
Comm Status
State |
Description |
Steady Off |
No PROFIBUS connection is established. See the Troubleshooting PROFIBUS topic for possible reasons. |
Steady Green |
A PROFIBUS connection is established. |
Note:
These are the only two LED states of the NET LED, but it is possible to
have the Net LED flashing or flickering green, which indicates that the
RMC75P is going on- and off-line on the PROFIBUS channel and generally
indicates a network or configuration problem.
See Also
RMC150 Overview | PROFIBUS Overview
Copyright © 2024 Delta Computer Systems, Inc. dba Delta Motion