RMC200 Registers, Files 8, 12: Indirect Data Map Registers
Use the Indirect Data Map Editor to edit the Indirect Data Map. The RMC200 Indirect Data Map includes 1024 registers.
TheIndirect Data Mapregisters are the registers that should be accessed at runtime by a PLC when reading or writing theIndirect Data. The Indirect Data MapDefinition contains the addresses of the referenced registers, not the data. Reading or writing to the Indirect Data MapDefinition registers will not access the Indirect Data.
n = 0-1023
Internal IEC |
Access |
Register Name |
|
Indirect Data Map |
|||
%MD8.n |
* |
* |
|
Indirect Data Map Definition |
|||
%MD12.n |
DINT |
* |
*The data types and access type of the Indirect Data Values registers are determined by the mapped registers.
See Also
RMC200 Register Map | Modbus Addressing | DF1 Addressing | FINS Addressing
Copyright © 2024 Delta Computer Systems, Inc. dba Delta Motion