RMC200 Registers, Files 24 and 25: Axis Definitions

The Axis Definitions are not intended to be directly accessed by the user. The preferred method of changing the axis definitions is to use the Axis Definitions dialog.

For highly advanced users, see the Axis Definition Registers topic for more details.

 

Internal

IEC
Address


Data Type

Register Name

%MD24.0-511

DWORD

Current Axis Definitions

(Read-Only)

%MD25.0-511

DWORD

Requested

Axis Definitions

 

The Current Axis Definitions and the Requested Axis Definitions will generally be the same except in two cases:

(1) The user has written to the requested block and intends to do a warm restart or burn to flash and do a cold restart, or

(2) The requested axis definitions found on startup are invalid for the current hardware configuration; in this case the Current Axis Definitions will be the default for the current hardware configuration.

 