RMC200 Registers, File 22: Plot Manager

This file contains the Plot Layout registers.

Internal

IEC
Address


Data Type

Access

Register Name

%MD22.0

DINT

Read/Write

ClosedNumber of Plots

Controls how many plots are active. Changing this value will cause the firmware to re-evaluate the layout of the plots to ensure that it has room for all the data in the plots. This may cause one or more plots to be reset.

The default for this register is 8.

%MD22.1

DINT

Read Only

ClosedMaximum Plots

This read-only value indicates how many plot templates can be defined at once.

CPU20L: 48

CPU40: 64 (32 prior to firmware 1.14.0)

%MD22.2

DINT

Read Only

ClosedMaximum Data Sets per Plots

This read-only value indicates the maximum number of data sets that be captured simultaneously by an individual plot.

CPU20L: 48

CPU40: 128 (32 prior to firmware 1.14.0)

%MD22.3

DINT

Read Only

ClosedMaximum Samples per Loop Time

This read-only value indicates the maximum number of total data set samples that are allowed per loop time across all plots.

CPU20L: 512

CPU40: 1024

%MD22.4

DINT

Read Only

ClosedPlot Pool Size

This read-only value indicates the size of the plot capture pool shared by all plots, in 32-bit values.

CPU20L: 12x1024x1024 = 12,582,912

CPU40: 48x1024x1024 = 50,331,648  (12,582,912 prior to firmware 1.14.0)

 

See Also

RMC200 Register Map | Modbus Addressing | DF1 Addressing | FINS Addressing


Send comments on this topic.