RMC200 Registers, File 21: Task Manager

Internal

IEC
Address


Data Type

Access

Register Name

%MD21.0

DINT

Read/Write

ClosedNumber of Tasks Allocated

0-32 (default = 2)

%MD21.1

DINT

Read/Write

ClosedProgram Triggers Task Enabled

0=false, 1= true (default = 1)

%MD21.2

DINT

Read/Write

ClosedTask Behavior on Axis Halt

Defines the Task Stop Mode:

0: Stop no tasks on axis halt

1: Stop all tasks on axis halt

2: Stop specific task(s) on axis halt (see TaskMask fields defined below (%MD21.10)

%MD21.3

DINT

Read/Write

ClosedStartup Mode

0=PROGRAM, 1=RUN (default = 0)

%MD21.4

DINT

Read/Write

ClosedRUN/PROGRAM Input

0 = None

1 = %IX1.0 (CPU input 0)

2 = %IX1.1 (CPU input 1)

%MD21.5

DINT

Read/Write

ClosedAuto-enable Axes

Selects whether all axes should be enabled automatically when the controller is enabled. Otherwise, axes must be enabled individually using the Enable/Disable Axis (97) command.


0=Disabled, 1=Enabled (default = 1)

%MD21.10

DWORD

Read/Write

ClosedAxis Halt Affected Task Bitmask

Bitmask indicating which tasks (Task0..Task31) are affected by the “Stop Specific Tasks” selection of %MD21.2 above.

%MD21.11

DWORD

Read/Write

ClosedAxis Halt Affected Task Bitmask Expansion

Bitmask indicating which tasks (Task32..Task63) are affected by the “Stop Specific Tasks” selection of %MD21.2 above.

 

See Also

RMC200 Register Map | Modbus Addressing | DF1 Addressing | FINS Addressing