Supported Axes: |
All |
See the Commands Overview topic for basic command information and how to issue commands from PLCs, HMIs, etc.
Command Parameters
# |
Parameter Description |
Range |
1 |
Plot Number |
any valid plot number |
2 |
Enable/Disable: Disable(0), Enable(1) |
0 or 1 |
Description
This command enables or disables the trigger for a plot. The automatic trigger and any triggers from the Trigger Plot (102) command will be disabled or enabled. The automatic trigger can only be disabled and enabled if it was already defined in the plot template.
To find out more on triggering, see the Triggering Plots topic.
See Also
Plot Overview | Triggering Plots | List of Commands | Commands Overview